Cooling System-Fan And Wind Scooperon Selection
1.Suction and exhaust fans: For equipment with higher speed, when the engine is installed in the front part of the equipment, the suction fan can be selected to make good use of the oncoming wind to enhance the cooling effect; when the engine is installed at the back end, generally choose the exhaust fan.
For equipment with low walking speed, you can choose suction fan or exhaust fan. In general, because the suction fan uses cooler air to cool the radiator, The efficiency is significantly higher than the exhaust fan.
2.Fan speed and diameter: With the same power consumption, the cooling effect and noise of low-speed and large fans are obviously better than that of high-speed and small fans. In addition, when choosing a fan, pay attention to the tip speed of the fan should not exceed 4200~5000 m/min.
3. المسافة بين المروحة وجوهر المبرد: شفط أكثر من 2 بوصة ، والعادم أكثر من 4 بوصات.
4- المسافة بين المروحة والمحرك: يجب أن تكون أبعد ما يمكن إذا سمحت المروحة بدعم لحظة الانحناء (7 نيوتن متر) ، ولكن لا يُسمح عمومًا بتجاوز سمك وسادة المروحة 3 بوصات.
5. يحظر استخدام غسالات تخفيف مرنة عند تركيب المروحة لمنع تلف شفة المروحة بسبب الإجهاد المركّز.
هناك ثلاثة أنواع شائعة الاستخدام من مغارف الرياح: نوع الصندوق ، والحلقة ، والحلق ، انظر الشكل أدناه.
1.يجب إحكام غلق مغرفة الرياح والرادياتير.
2-الفجوة بين طرف المروحة ومغرفة الرياح هي بشكل عام 1.5 ~ 2.5٪ من قطر المروحة ؛
3.موقع المروحة في مغرفة الرياح: شفط , 2/3 بوصة ، عادم ، 1/3 بوصة.